-40%
BACKLIGHTS X3 BACKLIGHT LUZ DE PANTALLA KORG X2 X3 X3R N264 N364
$ 12.93
- Description
- Size Guide
Description
Ebay and Paypal no longer sends us your email address. To receive the free generic instruction you must send your email address.YOU MIGHT FIND A CHEAPER BACKLIGHT
BUT YOU WON'T FIND A BETTER BACKLIGHT
MADE IN THE US
A
PROVIDES LIGHT
FOR
A
PPROX. 6000 HOURS
SEE FULL LIST OF INSTRUMENTS WITH REPLACEABLE BACKLIGHTS BELOW
WE NO LONGER ACCEPT INTERNATIONAL ORDERS
THROUGH US BASED FREIGHT FORWARDERS
International customers must call or email us directly (info below)
IF YOU DON'T SEE YOUR
INSTRUMENT AT THIS AUCTION
CHECK OUR OTHER AUCTIONS
THIS AUCTION IS FOR BACKLIGHTS THAT FIT INSIDE OF THE LCD DISPLAYS OF THE INSTRUMENTS LISTED BELOW
KORG:
N264 ( N-264 ), N364 ( N-364 ), X2 ( X-2 ), X3 ( X-3 ), X3r ( X-3r )
DO NOT PRY APART YOUR DISPLAY. DAMAGE MAY RESULT!!
CONTACT US IF YOU HAVE ANY QUESTIONS OR DO NOT SEE YOUR INSTRUMENT ON THE LIST
CONTACT INFORMATION IS LISTED BELOW.
Our backlights have the contacts in the correct position for your display. No messy jumpers needed.
There is minor soldering involved. Most people consider this a repair they can do themselves. You can also take your instrument to a service center and have them do it.
We ship to all worldwide locations serviced by the US post office. Shipping charges vary on international destinations. Ask for freight charges when ordering.
We also include an email of the contents of a CD that is free with a backlight order.
The email is a generic explanation of what to do once the display has been removed from the instrument. Your instrument may be different than what is shown but the principle is the same.
Again, DO NOT pry apart your display as damage may occur. The email is helpful when working on Korg, Akai, and other displays. ALL INFORMATION ABOUT TOOLS IS ON THE email.
LEGAL NOTICE: WE WILL NOT BE HELD RESPONSIBLE FOR ANY LOSS/ DAMAGE OR INJURY RESULTING FROM THE INSTALLATION OF REPLACEMENT BACKLIGHTS. IF YOU ARE IN ANY DOUBT AS TO YOUR ABILITY TO INSTALL THEM PLEASE REFER INSTALLATION TO SUITABLY QUALIFIED PERSONNEL. WHILE EVERY EFFORT IS MADE TO ENSURE THAT THIS INFORMATION IS CORRECT,WE CAN NOT BE HELD RESPONSIBLE FOR LOSS/DAMAGE OR INJURY RESULTING FROM ANY ERRORS CONTAINED WITHIN THIS INFORMATION.
You will most likely need a new backlight but make sure the inverter is working. An easy test is turn the instrument on in a very dark room. If there is even a slight glow the inverter is good. If there is no glow it could be the inverter or just a totally dead backlight. If the light is completely dead you need to check the inverter either at the backlight contact points or at the inverter voltage output pins to see if there is power going to the backlight (approx. 70-100vac @ 400hz). If there is power you only need a new backlight. If there is no power you need to fix the inverter circuit and it is very likely that you also need a new backlight. If you don't have proper test equipment you can order and install a new backlight (which you most likely need anyway) and if that doesn't fix it you will need to hunt down the problem in the inverter circuit.
TELESIS USED GEAR AND BACKLIGHTS
P.O. BOX 4414
Orange, CA 92863
US, and CANADA BIDDERS GO AHEAD AND BID